Cleaner air, continuously.
The FulCare plasma air sterilizer combines plasma disinfection with multi-stage filtration to reduce airborne viruses, bacteria and volatile organic compounds in occupied clinical spaces — without interrupting patient care.
- Continuous operation in wards, ICUs, operating theatres and laboratories.
- Five-stage purification and disinfection for particles, gases and microorganisms.
- Real-time air-quality sensing with cloud monitoring and remote management.
For occupied clinical spacesAir quality that supports infection control.
Airborne transmission is difficult to see and difficult to stop. The sterilizer works continuously in the background, reducing the microbial load while clinical teams focus on patient care.
Continuous protection
Runs while rooms are occupied, adding a layer of air disinfection to cleaning, ventilation and source-control measures.
Quiet, unobtrusive operation
Designed for patient rooms and clinical areas where equipment must operate without disrupting care or recovery.
Four coordinated stages.
Room air is drawn through the unit, treated and returned to the space. Each stage targets a different part of the contamination load.
Capture
Pre-filtration retains dust and larger particles before the air reaches the treatment stages.
Plasma
Plasma exposure inactivates airborne viruses and bacteria, including clinically relevant respiratory pathogens.
Polish
Multi-stage filtration captures fine particles and helps reduce odours and volatile organic compounds.
Monitor
Built-in sensors track air quality and support automatic operation and remote oversight.
Performance you can document.
Independent laboratory results support the disinfection claims used in clinical planning. Figures are based on controlled test conditions; site performance depends on room volume, layout and air changes.

Know what the air is doing.
Integrated sensors continuously report the parameters that matter in clinical spaces. The cloud platform supports remote diagnosis, group management and historical data review.
Where continuous air treatment matters.
Planning data at a glance.
| Parameter | Specification |
|---|---|
| Application | Occupied clinical spaces: OT, ICU, NICU, wards, CSSD, laboratories |
| Technology | Plasma disinfection with five-stage filtration |
| Virus inactivation | 99.81% MS2 at 60 min; 99.99% MS2 at 120 min; 99.95% H1N1 at 60 min |
| Airborne microorganisms | ≥90% reduction in a 120 m³ room; average ≤64.8 cfu/m³ after treatment |
| Air cleanliness | ISO 9 to ISO 8 in a 100 m³ room after 60 minutes |
| Ozone residue | ≤0.001 mg/m³ after one hour of operation |
| Monitoring | PM2.5, TVOC, CO₂, formaldehyde (HCHO) |
| Control | Smart cloud platform and mobile APP; remote diagnosis and data export |
| Installation | Clinical rooms, wards, theatres, laboratories and public hospital areas |
Performance values are based on controlled laboratory tests. Room volume, air changes, layout and operating conditions affect actual results. Confirm the configuration for your project with FulCare.
Talk to a FulCare specialist.
Share your room type, area and monitoring requirements. We will recommend a configuration and prepare a quotation.